EXHAUST GAS ANALYSERS 8060 TECHNICAL FEATURES:-
Accuracy: Class 0 ISO 3930 OIML R99 ed. 2000, where applicable
Zero Setting: automatic (frequency: automatic)
Calibration: automatic (frequency: according to the regulation)
Gas flow: min. 6 litres/minute
Condense separator: two stages group with coalescent filters (+ 1 additional filter to protect the pump)
Condense discharge: automatic and continuous
Flow check: automatic and continuous
Net voltage check: automatic and continuous of min voltage.
Leak test: automatic (frequency: according to the homologation)
Residual HC test: automatic (frequency: according to the homologation)
Response time: according to OIML with probe 6 meters length
Warming-up: automatic (max. warming-up time: 5 minutes) ENVIRONMENTAL
Operating Temp: 5-;.-40°C
Relative Humidity: <90% without condense
Atmospheric pressure: 700-;.-1100 hPa
Altitude: < 2000m
Level of pollution: 2 (according to EN 61010-1)
Storage Temp:
OTHER
Clock and calendar in rei time with buffer battery
Customisation for garage data: 9 lines of 24 types
Diagnosis of carburettor functionality (petrol, GPL, natural gas)
Catalyst test KIT MOTO 8047
Equipment kit accessories to carry out the exhaust gas analyser tests on motorcycle.